SEISMIC SAFETY

COMMENTARY ON UC SEISMIC SAFETY POLICY FOR LEASED AND PURCHASED FACILITIES
THE POLICY
- OBJECT OF THE POLICY. The object of the policy is life safety, not property protection. In other words, the standard does not assure that the property or its contents will be operational or undamaged after a major seismic event.
- POLICY IS COMPARABLE TO LOCAL/STATE/FEDERAL POLICY DIRECTION. The policy changes, for the most part, are comparable to those contemplated or implemented by local, state, and federal regulators in the wake of the Northridge earthquake.
- RE-EVALUATION OF CURRENTLY OWNED PROPERTY The new policy will not be retroactively applied to currently owned property. The seismic performance of existing facilities will be addressed in a survey of owned properties that is to be completed in the near future.
- APPLICABILITY TO PURCHASE OR LEASE TRANSACTIONS. The policy applies to purchases and to new leases (defined as newly leased space or lease renewals). The policy does not apply to the exercise of options to expand leased space or to extend the lease term that were negotiated prior to the implementation of the new policy. Purchases of single-family wood-frame houses are to be handled on a case-by-case basis (see below).
INDEPENDENT REVIEW
- SEISMIC PERFORMANCE RATING. The Independent Review states the licensed structural engineer's professional evaluation of the anticipated seismic performance of a structure during a “major seismic disturbance.” This is defined, for the purposes of the seismic performance ratings, as an earthquake at the site that would be given a Modified Mercalli Intensity Scale (modified by Charles F. Richter in 1958) rating of at least MM IX based on the description of the structural effects, except that an intensity of MM VIII can be utilized for facilities on the Davis campus.
Any to-be-purchased property shall be rated “Good” or the acquisition budget should be sufficient to retrofit the facility and raise it to the “Good” rating. Leased property should be rated “Fair” or “Good.” When leased property is initially rated “Poor” or “Very Poor” and seismic retrofitting is included in pre-occupancy construction, the facility should be brought up to a “Good,” rather than a “Fair” rating. (In most cases, the cost difference between upgrading a facility to “Good” rather than “Fair”is likely to be marginal.)
REQUIREMENTS FOR INDEPENDENT REVIEW
CERTIFICATION OF APPLICABLE CODE
- CERTIFICATION OF APPLICABLE CODE. The Certification of Applicable Code is designed to make it easier for the licensed architect, structural engineer or civil engineer to understand exactly what certification language must be included.
The design of the entire facility must be approved by the local jurisdiction. The design must include all additions, modifications and repairs to the seismic resisting systems. The term “entire facility” refers to all parts of a building or group of buildings that are interrelated. For instance, a one story L-shaped structure with a tower attached to it, even though not constructed at the same time, would be considered a single facility. An office building with a contiguous parking structure would be considered a single facility. For lease transactions, the entire facility is defined as the building or interrelated group of buildings containing the leased premises as well as any common areas as defined in the lease agreement. A separate and free standing parking structure may be considered part of the entire facility.
SINGLE-FAMILY WOOD-FRAME RESIDENCES
- CONVENTIONAL 1 OR 2 STORY WOOD FRAME CONSTRUCTION ON LEVEL SITES. Purchase or lease of conventionally constructed wood-frame one- and two-story single-family residences on sites with slopes less than 1-vertical to 3-horizontal are exempt from the UC Seismic Safety Policy. Most buildings of this class and scale of construction are highly redundant with many interior walls that act structurally. Life-threatening collapses seldom occur in these types of structures.
UNIVERSITY OF CALIFORNIA
CERTIFICATION OF APPLICABLE CODE
I, __________________________ an architect, structural engineer, or civil engineer, licensed by the State of California, have completed a recent walk-through of the facility and have reviewed the available documentation and hereby certify the following: that the design of the entire facility, known for purposes of this agreement as
(Premises Address Here)
including all additions, modifications, and/or repairs to the seismic resisting systems, was approved by the local jurisdiction pursuant to the 1976 or later edition of the Uniform Building Code. This facility was originally constructed in ____________________ (year). Additions/modifications/repairs took place in __________________ (year(s)) [if applicable].
I further certify that the facility does not contain any of the following: (i) unreinforced masonry; (ii) welded steel moment resisting frames; (iii) flexible diaphragm-rigid walls; (iv) apparent additions, or modifications, or repairs to the seismic resisting systems done without a permit; (v) hillside construction on a slope steeper than 1–vertical to 3–horizontal; or; (vi) multi-story wood frame apartment or condominium structures with construction over first-story parking (soft-story structures).
A copy of the certificate of occupancy is attached.
Printed Name ___________________________ License No. ____________________
Title ____________________________________________________
Signature _______________________________ Date _____________________
Firm Name and Address
___________________________________
___________________________________
___________________________________
AFFIX SEAL HERE
* Currently, this applies to welded steel moment frame structures in Santa Cruz and San Francisco built before 1989, and to those in Los Angeles built before 1994.